Air Diver Exam Prep
Free practice questions

Free ADC-AIR-DIVER Practice Questions

10 exam-style questions with answers and explanations, straight from our 1,030-question bank. Tap an answer to check yourself. When you're ready, take the scored version in the free practice test.

Start the free practice test → ★★★★★4.9/5 from 2,400+ candidates · No signup

Question 1

During a pre-dive helmet check, the inlet non-return valve permits gas flow in both directions. The demand regulator and exhaust valve function normally. If the umbilical's gas hose depressurized underwater, what hazard would this defect create?

Show answer & explanation

Correct answer: C - Breathing gas could escape from the helmet into the failed supply hose.

Question 2

Air hunger, a pounding headache, and irritability develop during heavy work at 78 fsw. The surface supply pressure remains normal. After the diver is recovered, inspection reveals that the helmet's oral-nasal mask had slipped away from the face. Which diagnosis best connects the equipment finding with the symptoms?

Show answer & explanation

Correct answer: A - Carbon dioxide retention from increased rebreathing within the helmet.

Question 3

An 80-fsw dock repair changes from a no-decompression dive to one with planned decompression. One diver will work from a fixed platform; no specialty hazard or additional staffing requirement has been identified. Under the ADCI surface-supplied air provisions, select the minimum personnel-and-chamber arrangement for the revised dive.

Show answer & explanation

Correct answer: D - Five-person dive team; an on-site double-lock chamber capable of 165 fsw.

Question 4

An intake pump is electrically locked out, but an open bypass still connects a full basin to a lower reservoir. No flow is visible at the water surface. The operator says the intake is safe because the pump cannot restart. Before a diver approaches the intake, which additional control addresses the remaining entrapment hazard?

Show answer & explanation

Correct answer: B - Isolate every flow path and verify that no pressure-driven flow remains at the intake.

Question 5

An adult diver is recovered unconscious and placed on deck. A qualified medical responder finds a definite carotid pulse within 10 seconds but no spontaneous breathing. The airway is open, and another crew member is activating emergency assistance. What respiratory support is indicated at this point?

Show answer & explanation

Correct answer: B - Give one assisted breath every 6 seconds, producing visible chest rise.

Question 6

A bailout cylinder provides 60 surface ft³ of air at 3,000 psig. Before a sea-level seawater dive to 99 fsw, it reads 2,400 psig; 600 psig must remain unusable, including all delivery and reserve allowances. The escape plan requires 7.5 minutes to reach another breathing source at that depth. Assume a surface-equivalent breathing rate of 1.5 ft³/min, 33 fsw per atmosphere, constant temperature, and gas volume proportional to cylinder gauge pressure. How long will the usable gas last, and does it cover the required escape?

Show answer & explanation

Correct answer: D - 6 minutes; insufficient for the required return to another breathing source.

Question 7

An oxygen-arc cutting job is planned beneath an inverted steel section. The section is fully submerged, but its underside can trap gases released during cutting. The electrode circuit, grounding, and tender-operated switch have passed inspection. What remaining preparation is essential before an arc is struck?

Show answer & explanation

Correct answer: A - Vent the overhead pocket so cutting gases cannot accumulate.

Question 8

Twenty minutes after completing a scheduled air dive, a diver develops tingling in both legs and difficulty walking. Oxygen is started while emergency transport and diving-medical consultation are arranged. The symptoms disappear before transport arrives. Which decision should be communicated to the transport crew?

Show answer & explanation

Correct answer: C - Continue oxygen and the urgent diving-medical assessment despite the improvement.

Question 9

A 0-300-fsw depth gauge is specified as accurate to ±0.5% of full scale. During its scheduled five-point ascending-and-descending calibration across the full range, the largest error is 1.0 fsw at a 60-fsw reference pressure. The reference instrument meets the required accuracy, and all other checks are satisfactory. How should the technician record this result?

Show answer & explanation

Correct answer: A - Acceptable: the permitted error is ±1.5 fsw throughout the scale.

Question 10

Bottom work is complete, but the working diver remains in the water on mandatory decompression stops. The designated standby diver's equipment is ready at the entry point. A deck foreman asks that diver to move stores at the far end of the barge. How should the standby diver respond?

Show answer & explanation

Correct answer: C - Remain at the entry station and follow the dive until the working diver is out of the water.

That's 10 of 1,030

The full bank has 1,020 more ADC-AIR-DIVER questions with explanations.

Continue in the free practice test →

View plans